Prealbumin Assay Kit(PALB)

For the in vitro quantitative determination of Prealbumin(transthyretin) in human serum.

Regulatery Status: CE

Product Catalog Number Packaging Method/Format
Product Catalog No: Kit (80ml) Pack Size: GB630M Pack Size: R1:3×20 ml
R2:1×20 ml
Pack Size: Immunoturbidimetric
Product Catalog No: Kit (80ml) Pack Size: GS631M Pack Size: R1:3×20 ml
R2:1×20 ml
Product Catalog No: Kit (80ml) Pack Size: GT631M Pack Size: R1:3×20 ml
R2:1×20 ml
Product Catalog No: Kit (240ml) Pack Size: GB630M/B Pack Size: R1:3×60 ml
R2:3×20 ml
Product Catalog No: Kit (240ml) Pack Size: GS631M/B Pack Size: R1:3×60 ml
R2:3×20 ml
Product Catalog No: Kit (48.8ml) Pack Size: GD631M Pack Size: R1:8×3.8 ml
R2:4×2.6 ml
Pack Size:
Pack Size:
Pack Size:
Pack Size:

Category:
Product Features

Prealbumin (transthyretin) is a tryptophan-rich 55KDa protein synthesized in liver hepatocytes and functions primarily as a binding and transport protein. The small body pool, short half-life and easy quantification on existing laboratory equipment make Prealbumin the preferred marker of visceral protein status. Measurement of Prealbumin levels in serum may aid in the assessment of the nutritional status of the patient.

Assay Principle

Neat sample is incubated with assay buffer before the addition of antibody reagent, specific for human prealbumin. The absorbance of the resulting turbid solution is read at 340 nm and is proportional to the concentration of prealbumin in the sample. By constructing a standard curve from the absorbance of known standards, the actual concentration of prealbumin in the sample can be determined.

Order Enquiry

Order Enquiry Form

References

1. Mears, E. Outcome of a continuous process improvement of a nutritional Care Program incorporating Serum Prealbumin Measurements. Nutritional Investigation, (1996);12 :479-484

2. Tietz, NW.(ed.). Clinical Guide to Laboratory Tests, third reprint Philadelphia, PA:WB Saunders, (1995) : 608-9

3. Hutchinson, DR., Halliwell, RP., Smith, MG. and Parke, DV. Serum “Prealbumin” as an index of liver function in human hepatobiliary disease. Clin Chim Acta, (1981): 114:69-74

4. Hamlin, CR. and Pankowsky, DA. Turbidimetric determination of Transthyretin(Prealbumin) with a centrifugal analyser. Clinical Chemistry, (1986); 33/1:144-146

5. Consensus of a group of Professional societies and Diagnostic companies on Guidelines for interim reference ranges for 14 proteins in serum based on the standardisation against the IFCC/BCR/CAP Reference Material (CRM 470). Eur. J. Clin. Chem. Clin. Biochem., (1996); 34: 517-520

6. Glick, MR. et al. Clinical Chemistry, (1986); 32:470-475

Enquiry