Immunoglobulin Free Light Chains Kappa and Lambda Human ELISA

Regulatery Status: RUO
Type: Sandwich ELISA, Biotin-labelled antibody
Other Names Status: FLC
Species: Human
Catalog No Size
Product Catalog No: RD194088100R Pack Size: 96 wells (1 kit)

Pack Size:
Pack Size:
Pack Size:
Pack Size:

Category:
Product Features

Human immunoglobulin molecules consist of two identical heavy chains which define immunoglobulin classes (IgG, IgA, IgM, IgD and IgE) and identical light chains (kappa or lambda) that are covalently linked to a heavy chain. In healthy individuals, the majority of light chains in serum exist bound to heavy chain. However, low levels of free light chains (FLCs) are found in serum of normal individuals due to their excess production over heavy chains by mature B-cells. In serum, FLC kappa exists predominantly as a monomer with a molecular weight of 22.5 kDa and FLC lambda as a dimer with a molecular weight of 45 kDa. This size difference results in a differential glomerular filtration rate and, consequently, a ratio of FLC kappa to FLC lambda of 1:1.6 in serum.

FLCs are observed in urine too but filtration and reabsorption of low molecular proteins in the kidney strongly affects the FLC concentration so that urinary FLC level is low in healthy individuals.

FLC are a natural product of B lymphocytes and, as such, represent a unique biomarker of neoplastic and reactive B cell-related disorders. Increased FLCs are associated with malignant plasma dyscrasia and other lymphocyterelated immunoproliferative disorders.

The detection of the FLCs is important diagnostic aid for a variety of monoclonal gammopathies, such as multiple myeloma, Waldenstrom macroglobulinemia, nonsecretory myeloma, smoldering multiple myeloma, monoclonal gammopathy of undetermined significance. Accurate measurement of monoclonal free light chains in serum and/or urine is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light chain-deposition disease. The ability to quantify monoclonal FLCs may be useful to monitor the disease. In patients with light chain myeloma, either of light chain, kappa or lambda, is dominantly produced and resulting in marked changes of the FLC κ/λ ratio in the early phase of the disease. The detection of urinary monoclonal kappa or lambda free light chains of immunoglobulin, also know as Bence Jones proteins (BJP), are important for identifying and monitoring Bcell malignancies too.

In addition, compared with the healthy state, the synthesis of polyclonal FLC is markedly increased in conditions associated with B cell activation as found in certain inflammatory or autoimmune diseases (e.g. systemic lupus erythematosus, rheumatoid arthritis, or multiple sclerosis, as well as in cancer, diabetes mellitus, and AIDS).

Features

  • Intended for research use only.
  • The total assays time is less than 3.5 hours.
  • The kit measures FLC kappa and FLC lambda in serum, plasma and urine.
  • Components of the kit are provided ready to use, concentrated and lyophilized.
  • Calibrators and Quality Controls are human serum based.

Research topic

Autoimmunity, Oncology

Techical Sheet / Info

Type

Sandwich ELISA, Biotin-labelled antibody

Applications

Serum, Plasma-EDTA, Plasma-Heparin, Plasma-Citrate, Urine

Sample Requirements

2×5 µl/well

Storage/Expiration

Store the kit at 2–8°C. Under these conditions, the complete kit is stable until the expiration date (see label on the box).

Calibration Curve

Calibration Range

10–320 µg/l (FLC kappa)
17.5–560 µg/l (FLC lambda)

Limit of Detection

FLC kappa ELISA Limit of detection (LOD) (defined as concentration of analyte giving absorbance higher than mean absorbance of blank plus three standard deviations of the absorbance of blank: Ablank + 3×SDblank) is calculated from the real FLC kappa values in wells and is 6 μg/L.

FLC lambda ELISA Limit of detection (LOD) (defined as concentration of analyte giving absorbance higher than mean absorbance of blank plus three standard deviations of the absorbance of blank: Ablank + 3×SDblank) is calculated from the real FLC lambda values in wells and is 5 μg/L.

Intra-assay (Within-Run)

n = 8;
CV = 3.0% (FLC kappa)
CV = 4.5% (FLC lambda)

Inter-assay (Run-to-Run)

n = 6;
CV = 7.0% (FLC kappa)
CV = 6.4% (FLC lambda)

Spiking Recovery

101.4% (FLC kappa)
100.9% (FLC lambda)

Dilutation Linearity

87.8% (FLC kappa)
85.8% (FLC lambda)

Crossreactivity

bovine    Non-detectable
cat       Not tested
goat      Non-detectable
horse     Non-detectable
dog       Not tested
hamster   Not tested
mouse     Non-detectable
pig       Non-detectable
rabbit    Non-detectable
rat       Non-detectable
sheep     Non-detectable
chicken   Not tested
monkey    Not tested
human     Yes
Order Enquiry

    Order Enquiry Form

    References

    – Cambridge G, Perry HC, Nogueira L, Serre G, Parsons HM, De La Torre I, Dickson MC, Leandro MJ, Edwards JC. The effect of B-cell depletion therapy on serological evidence of B-cell and plasmablast activation in patients with rheumatoid arthritis over multiple cycles of rituximab treatment. J Autoimmun. 2014 May;50:67-76

    – Franco DA, Truran S, Burciu C, Gutterman DD, Maltagliati A, Weissig V, Hari P, Migrino RQ. Protective role of clusterin in preserving endothelial function in AL amyloidosis. Atherosclerosis. 2012 Nov;225 (1):220-3

    – Yu HR, Kuo HC, Huang EY, Liang CD, Hwang KP, Lin IC, Sheen JM, Wang TJ, Wang CL, Yang KD. Plasma clusterin levels in predicting the occurrence of coronary artery lesions in patients with Kawasaki disease. Pediatr Cardiol. 2010 Nov;31 (8):1151-6

    – Yu HR, Kuo HC, Sheen JM, Wang L, Lin IC, Wang CL, Yang KD. A unique plasma proteomic profiling with imbalanced fibrinogen cascade in patients with Kawasaki disease. Pediatr Allergy Immunol. 2009 Nov;20 (7):699-707

    – Zeman D, Kusnierova P, Svagera Z, Vsiansky F, Byrtusova M, Hradilek P, Kurkova B, Zapletalova O, Bartos V. Assessment of Intrathecal Free Light Chain Synthesis: Comparison of Different Quantitative Methods with the Detection of Oligoclonal Free Light Chains by Isoelectric Focusing and Affinity-Mediated Immunoblotting. PLoS One. 2016;11 (11):e0166556

    Enquiry